.Purpose: To evaluate the impact of locator attachments with different retentive insert materials on bite force in mandibular implant overdenture. Materials and Methods: Eight completely edentulous patients were selected for this study. Each patient received two implants in the canine area of the mandible bilaterally. Patient grouping was performed as follow, group Ι: 4 patients received two locator overdenture attachments with nylon inserts, group ΙΙ: 4 patients received two locator overdenture attachments with PEEK inserts. The bite force was measured with conventional complete denture, after 3 months of overdenture insertion and after 6 months using occlusal force transducer. The surface wear evaluation of PEEK and nylon inserts were done before pick-up, after 3 months and after 6 months of overdenture insertion using scanning electron microscope (SEM). Results: There was significant difference between groupI(nylon insert) and groupII (PEEK insert).Overdentures loaded with PEEK inserts recorded significant increase in bite force values than nylon inserts after 3 months and 6 months of overdenture insertion(P<0.001). Significant wear changes were shown with nylon inserts at (T3) and (T6) rather than PEEK inserts(P<0.001). Conclusion:PEEK inserts in locator attachments provide successful inserts instead of nylon ones providing better biteforce and wear resistence
M., A., Y., A., N., E. M., & A., H. (2021). Impact of Locator Attachments with Different Retentive Insert Materials on Bite Force in Mandibular Implant Overdenture. Egyptian Journal of Oral and Maxillofacial Surgery, 12(4), 245-254. doi: 10.21608/omx.2022.109075.1145
MLA
Abdelaziz M.; Altonbary Y.; El Mekawy N.; Hegazy A.. "Impact of Locator Attachments with Different Retentive Insert Materials on Bite Force in Mandibular Implant Overdenture", Egyptian Journal of Oral and Maxillofacial Surgery, 12, 4, 2021, 245-254. doi: 10.21608/omx.2022.109075.1145
HARVARD
M., A., Y., A., N., E. M., A., H. (2021). 'Impact of Locator Attachments with Different Retentive Insert Materials on Bite Force in Mandibular Implant Overdenture', Egyptian Journal of Oral and Maxillofacial Surgery, 12(4), pp. 245-254. doi: 10.21608/omx.2022.109075.1145
VANCOUVER
M., A., Y., A., N., E. M., A., H. Impact of Locator Attachments with Different Retentive Insert Materials on Bite Force in Mandibular Implant Overdenture. Egyptian Journal of Oral and Maxillofacial Surgery, 2021; 12(4): 245-254. doi: 10.21608/omx.2022.109075.1145